Diagnostic Test
- TEST FOR INTERMITTENT CONDITION
- With the scan tool, record and erase DTCs
- Operate the Passenger Door Lock Switch in all positions several times.
- Turn the ignition on and wait 30 seconds.
- With the scan tool, read DTCs.
Does the scan tool display B1809-PASSENGER DOOR LOCK/UNLOCK SWITCH CIRCUIT STUCK UNLOCK?
Yes
- Go to step 2
No
- The conditions that caused this code to set are not present at this time. Using the wiring diagram/schematic as a guide, inspect the wiring and connectors.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure .
- DOOR LOCK SWITCH SHORTED
- With the scan tool, erase DTCs.
- Disconnect the Passenger Express Window/Door Lock Switch connector.
- With the scan tool, read DTCs.
Does the scan tool display B1809-PASSENGER DOOR LOCK/UNLOCK SWITCH CIRCUIT STUCK UNLOCK?
No
- Replace the Passenger Express Window/Door Lock Switch.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure .
Yes
- Go to step 3
- (G160) PASSENGER DOOR LOCK SWITCH MUX CIRCUIT SHORT TO GROUND
- Turn the ignition off.
- Disconnect the Cluster C1 connector.
- Measure the resistance between ground and the (G160) Passenger Door Lock Switch Mux circuit.
Is the resistance below 10,000 ohms?
Yes
- Repair the (G160) Passenger Door Lock Switch Mux circuit for a short to ground.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure .
No
- Go to step 4
- (G160) PASSENGER DOOR LOCK SWITCH MUX CIRCUIT SHORT TO (P37) PASSENGER DOOR LOCK SWITCH RETURN CIRCUIT Fig 3: Measuring Resistance Between Passenger Door Lock Switch MUX Circuit And Passenger Door Lock Switch Return Circuit
Courtesy of CHRYSLER LLC
- Disconnect the Cluster C2 connector.
- Measure the resistance between the (G160) Passenger Door Lock Switch Mux circuit and the (P37) Passenger Door Lock Switch Return circuit.
Is the resistance below 10,000 ohms?
Yes
- Repair the (G160) Passenger Door Lock Switch Mux circuit for a short to the (P37) Passenger Door Lock Switch Return circuit.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure .
No
- Replace the Instrument Cluster in accordance with the Service Information.