DTC 85: Blower Not On High During Cooldown Test: Notes
For complete wiring diagrams refer to:
- SYSTEM WIRING DIAGRAMS for 300.
- SYSTEM WIRING DIAGRAMS for Charger.
- When Monitored:
When executing the Cool down Test.
- Set Condition:
If the A/C Heater Control sensed that the blower was not operating at high speed while the Cool down Test was running.
| Possible Causes |
|---|
| BLOWER CONTROL DID NOT REMAIN ON THE HIGH SPEED SETTING DURING THE ENTIRE COOL DOWN TEST |
| BLOWER MOTOR / RELATED CIRCUITS |
| (C850) BLOWER SWITCH POSITION SIGNAL CIRCUIT SHORTED TO (Z908) GROUND CIRCUIT |
| (C850) BLOWER SWITCH POSITION SIGNAL CIRCUIT SHORTED TO (Z909) GROUND CIRCUIT |
| (C850) BLOWER SWITCH POSITION SIGNAL CIRCUIT SHORTED TO GROUND |
| (C850) BLOWER SWITCH POSITION SIGNAL CIRCUIT OPEN |
| A/C HEATER CONTROL |
NOTE:
This DTC will display as active if the ignition is not cycled after running the Cool down Test. Otherwise, it will display as stored until cleared.