DTC 82: Sensor Too Cold To Start Cooldown Test: Notes
For complete wiring diagrams refer to:
- SYSTEM WIRING DIAGRAMS for 300.
- SYSTEM WIRING DIAGRAMS for Charger.
- When Monitored:
When executing the Cool down Test.
- Set Condition:
If the A/C Heater Control senses that the evaporator temperature is below 18.3°C (65°F) when executing the Cool down Test.
| Possible Causes |
|---|
| FAULTS PRESENT IN THE HVAC SYSTEM |
| EVAPORATOR TEMPERATURE BELOW 18.3°C (65°F) AT START OF COOL DOWN TEST |
| HIGH RESISTANCE ON (C121) SENSOR GROUND CIRCUIT |
| HIGH RESISTANCE ON (C21) EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT |
| EVAPORATOR TEMPERATURE SENSOR |
| A/C HEATER CONTROL |
NOTE:
This DTC will display as active if the ignition is not cycled after running the Cool down Test. Otherwise, it will display as stored until cleared.