Diagnostic Test
- VERIFY THAT ALL OF THE COOL DOWN TEST PREREQUISITES WERE MET
- Review the list of Cool down Test prerequisites.
- DTC 31 or 32 must not be active.
- The refrigerant system must be adequately charged.
- The blower motor must operate correctly in all speeds.
- The work area ambient temperature must be above 18.3°C (65°F).
- The evaporator temperature must be above 18.3°C (65°F).
- The A/C compressor must be turned off.
Were all of the prerequisites met before running the Cool down Test?
Yes
- Go to step 2
No
- Run the cool down test.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure .
- Review the list of Cool down Test prerequisites.
- CHECK FOR DTCs IN THE PCM
- With the scan tool, select PCM.
Are any DTCs present in the PCM?
Yes
- Diagnose any DTCs.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure .
No
- Refer to the Service Information for additional Cool down Test related diagnostic information and testing procedures. Run the Cool down Test again after the repair is complete.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure .
- With the scan tool, select PCM.