DTC 31: Evaporator Sensor Open: Notes
For complete wiring diagrams refer to:
- SYSTEM WIRING DIAGRAMS for 300.
- SYSTEM WIRING DIAGRAMS for Charger.
- When Monitored:
With the ignition on.
- Set Condition:
If the Evaporator Temperature Sensor input is out of range toward the high voltage threshold.
| Possible Causes |
|---|
| (C21) EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT SHORTED TO VOLTAGE |
| (C21) EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT OPEN |
| (C121) SENSOR GROUND CIRCUIT OPEN |
| EVAPORATOR TEMPERATURE SENSOR |
| A/C HEATER CONTROL |
NOTE:
This DTC must be active for the results of this test to be valid. Do not perform this test if this DTC is stored. Refer to HVAC SYSTEM TEST (MTC) .