LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2009 >> 300 Signature Series >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> (HVAC Systems (MTC) - Electrical Diagnostics) >> DTC Troubleshooting >> DTC 31: Evaporator Sensor Open >> Diagnostic Test

Diagnostic Test

  1. CHECK (C21) EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT FOR A SHORT TO VOLTAGE 
    Fig 1: Checking Evaporator Temperature Sensor Signal Circuit For A Short To Voltage
    GC0096376Courtesy of CHRYSLER LLC
    1. Turn the ignition off.
    2. Disconnect the A/C Heater Control C2 harness connector.
    3. Turn the ignition on.
    4. Measure the voltage of the (C21) Evaporator Temperature Sensor Signal circuit.

      Is the voltage above 0.2 volts?

      Yes 

      No 

      • Go to step  2
  2. CHECK (C21) EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT, (C121) SENSOR GROUND CIRCUIT, AND EVAPORATOR TEMPERATURE SENSOR 
    Fig 2: Checking Evaporator Temperature Sensor Signal Circuit, Sensor Ground Circuit & Evaporator Temperature Sensor
    GC0096377Courtesy of CHRYSLER LLC
    1. Turn the ignition off.
    2. Measure the resistance between the (C21) Evaporator Temperature Sensor Signal circuit and the (C121) Sensor Ground circuit in the A/C Heater Control C2 harness connector. The approximate circuit resistance should be as follows:
      • 1468 ohms @ 40°C (104°F)
      • 1800 ohms @ 35°C (95°F)
      • 2221 ohms @ 30°C (86°F)
      • 2757 ohms @ 25°C (77°F)
      • 3443 ohms @ 20°C (68°F)
      • 4330 ohms @ 15°C (59°F)
      • 5485 ohms @ 10°C (50°F)
      • 6998 ohms @ 5°C (41°F)
      • 7354 ohms @ 4°C (39°F)
      • 7731 ohms @ 3°C (37°F)
      • 8130 ohms @ 2°C (36°F)
      • 8553 ohms @ 1°C (34°F)
      • 9000 ohms @ 0°C (32°F)

      Is the resistance within the specifications?

      Yes 

      No 

      • Go to step  3
  3. CHECK (C21) EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT, (C121) SENSOR GROUND CIRCUIT, AND EVAPORATOR TEMPERATURE SENSOR 
    Fig 3: Checking Evaporator Temperature Sensor Signal Circuit, Sensor Ground Circuit & Evaporator Temperature Sensor
    GC0096378Courtesy of CHRYSLER LLC
    1. Disconnect the Evaporator Temperature Sensor harness connector.
    2. Measure the resistance of the (C21) Evaporator Temperature Sensor Signal circuit between the Evaporator Temperature Sensor harness connector and the A/C Heater Control C2 harness connector.

      Is the resistance below 5.0 ohms?

      Yes 

      • Go to step  4

      No 

  4. CHECK (C121) SENSOR GROUND CIRCUIT FOR AN OPEN 
    Fig 4: Checking Sensor Ground Circuit For An Open
    GC0096379Courtesy of CHRYSLER LLC
    1. Measure the resistance of the (C121) Sensor Ground circuit between the Evaporator Temperature Sensor harness connector and the A/C Heater Control C2 harness connector.

      Is the resistance below 5.0 ohms?

      Yes 

      No