Diagnostic Test
- CHECK FOR ACTIVE CONTROL CIRCUIT/PERFORMANCE AND CONTROL CIRCUIT OPEN DTCs
- Turn the ignition on.
- With the scan tool, read active HVAC DTCs.
Does the scan tool display any active: XXXX CONTROL CIRCUIT/PERFORMANCE or XXXX CONTROL CIRCUIT OPEN DTCs?
Yes
- Diagnose and repair the DTCs.
No
- Go to step 2
- RUN ACTUATOR CALIBRATION TEST
- With the scan tool, select System Tests and then select Actuator Calibration Test. When the test is complete, select View DTCs.
Does the scan tool display any DTCs?
Yes
- Diagnose and repair the DTCs. Refer to the DIAGNOSTIC CODE INDEX for a complete list of all HVAC related symptoms.
No
- Go to step 3
- With the scan tool, select System Tests and then select Actuator Calibration Test. When the test is complete, select View DTCs.
- CHECK MODE, BLEND AND RECIRCULATION DOOR OPERATION
- Start the engine.
- Set the blower to high speed.
- Verify that air flows from the correct vents while setting the Mode control to the Panel position, the Bilvel position, the Floor/Defrost position, and the Defrost position. Then, repeat in the opposite direction.
- Set the Mode control to the Panel position.
- Set the Driver Blend control to the full cold position.
- Set the Passenger Blend control the full cold position.
- Verify that the airflow air temperature changes while setting the Driver Blend control to the full hot position. Then, repeat in the opposite direction.
- Verify that the airflow air temperature changes while setting the Passenger Blend control to the full hot position. Then, repeat in the opposite direction.
- Set the Mode control to any position between Floor and Panel.
- Press the Recirc function on. Verify that the sound of the airflow gets louder as the recirculation door opens to bring in recirculated air.
- Press the Recirc function off. Verify that the sound of the airflow gets softer as the recirculation door closes to bring in fresh air.
Does each door operate properly?
Yes
- The condition causing the fault has cleared at this time.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure
No
- Remove the door actuator of the affected door from the A/C Heater Housing Assembly. By hand, attempt to rotate the actuator in both directions. Inspect the A/C Heater Housing for damage, for disconnected, missing, or broken linkage, and for broken or binding doors. Repair as necessary in accordance with the Service Information.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure