  1. VERIFY DTC B1083-HVAC MUX CIRCUIT HIGH IS ACTIVE 
    1. Turn the ignition on.
    2. With the scan tool, erase CCN DTCs.
    3. Turn the ignition off, wait 10 seconds, and turn the ignition on.
    4. With the scan tool, read CCN DTCs.

      Does the scan tool display active: B1083-HVAC MUX CIRCUIT HIGH?

      Yes 

      • Go To  2

      No 

  2. CHECK (C105) HVAC MUX CONTROL CIRCUIT VOLTAGE AT A/C HEATER CONTROL C1 HARNESS CONNECTOR 
    Fig 1: Checking HVAC MUX Control Circuit Voltage At A/C Heater Control C1 Harness Connector
    GC0096346Courtesy of CHRYSLER LLC
    1. Turn the ignition off.
    2. Disconnect the A/C Heater Control C1 harness connector.
    3. Turn the ignition on.
    4. Measure the voltage of the (C105) HVAC MUX Control circuit.

      What is the voltage?

      Below 4.8 Volts 

      • Go to step  3

      4.8 to 5.2 Volts 

      Above 5.2 Volts 

      • Go to step  4
  3. CHECK (C105) HVAC MUX CONTROL CIRCUIT FOR AN OPEN 
    Fig 2: Checking HVAC MUX Control Circuit For An Open
    GC0096347Courtesy of CHRYSLER LLC
    1. Turn the ignition off.
    2. Disconnect the Instrument Cluster C2 harness connector.
    3. Measure the resistance of the (C105) HVAC MUX Control circuit between the A/C Heater Control C1 harness connector and the Instrument Cluster C2 harness connector.

      Is the resistance below 5.0 ohms?

      Yes 

      No 

  4. CHECK (C105) HVAC MUX CONTROL CIRCUIT FOR A SHORT TO VOLTAGE 
    Fig 3: Checking HVAC MUX Control Circuit Voltage At A/C Heater Control C1 Harness Connector
    GC0096346Courtesy of CHRYSLER LLC
    1. Turn the ignition off.
    2. Disconnect the Instrument Cluster C2 harness connector.
    3. Turn the ignition on.
    4. Measure the voltage of the (C105) HVAC MUX Control circuit.

      Is the voltage above 0.2 volts?

      Yes 

      No