LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2009 >> 300 Signature Series >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 2 (42RLE Automatic Transmission (Service Information)) >> Diagnosis and Testing >> Hydraulic Pressure Tests >> Test Six-Selector In Reverse

Test Six-Selector In Reverse

WARNING: This page is about a different variant/trim than selected.
NOTE: This test checks the reverse clutch hydraulic circuit.
  1. Attach gauge to the reverse and low/reverse clutch tap.
  2. Move selector lever to the REVERSE position.
  3. Read reverse clutch pressure with output stationary (foot on brake) and throttle opened to achieve 1500 RPM.
  4. Reverse and low/reverse clutch pressure should read 165 to 235 psi.