Refrigerant Oil Level
When an A/C system is assembled at the factory, all components except the A/C compressor are refrigerant oil free. After the refrigerant system has been charged and operated, the refrigerant oil in the A/C compressor is dispersed throughout the refrigerant system. The A/C accumulator, A/C evaporator, A/C condenser and the A/C compressor will each retain a significant amount of the needed refrigerant oil.
It is important to have the correct amount of refrigerant oil in the A/C system. This ensures proper lubrication of the A/C compressor. Too little oil will result in damage to the A/C compressor, while too much oil will reduce the cooling capacity of the A/C system and consequently result in higher discharge air temperatures.
It will not be necessary to check the oil level in the A/C compressor or to add oil, unless there has been an oil loss. An oil loss may occur due to component replacement, or a rupture or leak from a refrigerant line, connector fitting, component or component seal. If a leak occurs, add 30 milliliters (1 fluid ounce) of the recommended refrigerant oil to the refrigerant system after the repair has been made. Refrigerant oil loss will be evident at the leak point by the presence of a wet, shiny surface around the leak.
Refrigerant oil must be added when an A/C accumulator, A/C evaporator or A/C condenser is replaced. See the Refrigerant Oil Capacities . When an A/C compressor is replaced, the refrigerant oil must be drained from the old compressor and measured. Drain all of the refrigerant oil from the new A/C compressor, then fill the new compressor with the same amount of refrigerant oil that was drained out of the old compressor.
| Component | ml. | oz. |
|---|---|---|
| Total System Fill | 180 | 6.1 |
| A/C Accumulator | 30 | 1.0 |
| A/C Condenser | 30 | 1.0 |
| A/C Evaporator | 60 | 2.0 |
| A/C Compressor | Drain and measure the oil from the old compressor - (Refer to REFRIGERANT OIL LEVEL) . | |