Diagnostic Test
WARNING: This page is about a different car, the 2010 Dodge Charger and 2010 Chrysler 300. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK FOR AN ACTIVE DTC
- Turn the ignition on.
- With the scan tool, record and erase DTCs.
- Activate the Panel Illumination.
- Wait 30 seconds.
- With the scan tool, read DTCs.
Does the scan tool display this DTC as active?
Yes
- Go to step 2
No
- The condition that caused this code to set is not present at this time. Check for an intermittent condition by inspecting the related wiring harness for chafed, pierced, pinched, and partially broken wires. Also inspect the related connectors for broken, bent, pushed out, spread, corroded, or contaminated terminals.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure
- PANEL ILLUMINATION COMPONENT SHORTED TO GROUND NOTE: Using the wiring diagram as your guide, disconnect each component one at a time and check for an active DTC.
- Turn the ignition off.
- Disconnect the component harness connector.
- Turn the ignition on.
- Activate the Panel Illumination.
- With the scan tool, read DTCs.
Does the scan tool display this DTC as active?
Yes
- Once all components are disconnected: Go To 3
No
- Replace the appropriate component in accordance with the Service Information.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure
- CHECK THE (E12) PANEL LAMPS DRIVER CIRCUIT FOR A SHORT TO GROUND
- Turn the ignition off.
- Disconnect the Cluster C3 harness connector.
- With all the above components disconnected, measure the resistance to ground of the (E12) Panel Lamps Driver Circuit from the Cluster C3 harness connector.
Is the resistance less than 10K ohms?
Yes
- Repair the (E12) Panel Lamps Driver circuit for a short to ground.
- Perform the BODY VERIFICATION TEST. Refer to DTC-Based Diagnostics/MODULE, Totally Integrated Power (TIPM) - Standard Procedure
No
- Replace the Cluster in accordance with the Service Information.