HVAC Systems (Service Information): Distribution: Motor-Blower: Installation
Courtesy of DAIMLERCHRYSLER CORP.
- Position the blower motor into the bottom of the HVAC housing.
- Install the three screws (2) that secure the blower motor (1) to the HVAC housing. Tighten the screws to 2 N.m (17 in. lbs.).
- Reach through the glove box opening and engage the connector for the blower motor wire harness leads (3) to the retainer located on the HVAC housing.
- Connect the instrument panel wire harness connector to the blower motor wire harness connector and engage the connector lock.
- Install the glove box, (Refer to BODY/INSTRUMENT PANEL/BIN-GLOVE BOX - INSTALLATION)
.
- Install the passenger side instrument panel silencer, (Refer to BODY/INSTRUMENT PANEL/SILENCER-INSTRUMENT PANEL - INSTALLATION)
.
- Reconnect the negative battery cable.