Home >> Chrysler >> 2006 >> PT Cruiser Base, 2D Convertible, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 56 ((HVAC Systems - Electrical Diagnostics)) >> 24 - HVAC - Electrical Diagnostics >> DTC Troubleshooting >> B10EC-Blower Motor Control Circuit OVERCURRENT (TIPM) >> Diagnostic Test

Diagnostic Test

WARNING: This page is about a different car, the 2007 Chrysler PT Cruiser. However, it is still accessible from the selected car via links, so may be relevant.
  1. 1) CHECK FOR AN ACTIVE OR STORED DTC B10E9 BLOWER MOTOR CONTROL CIRCUIT LOW IN THE TIPM 

    Turn the ignition on.

    With the scan tool, read TIPM DTCs.

    Does the scan tool display active or stored DTC B10E9 BLOWER MOTOR CONTROL CIRCUIT LOW? 

    Yes 

    1. Diagnose and repair the DTC. Refer to DIAGNOSTIC CODE INDEX  for a complete list of HVAC related symptoms.

    No 

    1. Go to  2).
  2. 2) INSPECT THE TIPM & BLOWER MOTOR CONNECTOR TERMINALS & WIRE HARNESS FOR A CONDITION CAUSING HIGH CIRCUIT RESISTANCE 
    Fig 1: TIPM C8 Harness Connector
    GC0043269Courtesy of CHRYSLER LLC

    Turn the ignition off.

    Disconnect the TIPM C8 harness connector.

    Disconnect the Blower Motor harness connector.

    Inspect the connector terminals for signs of corrosion build up and damage.

    Visually inspect the wiring harness for any chafed, pierced, pinched or partially broken wires hidden in the wire insulation.

    Were any of the above conditions found? 

    Yes 

    1. Repair as necessary.
    2. Perform BODY VERIFICATION TEST - VER 1 .

    No 

    1. Go to  3).
  3. 3) CHECK THE (C7) BLOWER MOTOR CONTROL CIRCUIT FUNCTION 
    Fig 2: Probing Blower Motor Control Output Circuit
    GC0043270Courtesy of CHRYSLER LLC

    Connect one end of a jumper wire to the (C7) Blower Motor Control circuit in the Blower Motor harness connector and connect the other end of the jumper wire to a clean chassis ground.

    NOTE: The test light should be illuminated and bright. Compared the brightness to that of a direct connection to the battery.

    Using a 12-volt test light connected to 12 volts, probe the (C7) Blower Motor Control Output circuit in the TIPM C8 harness connector.

    Does the test light illuminate brightly? 

    Yes 

    1. Go to  4).

    No 

    1. Repair the (C7) Blower Motor Control circuit for high resistance.
    2. Perform BODY VERIFICATION TEST - VER 1 .
  4. 4) CHECK (C70) BLOWER MOTOR HIGH SPEED CIRCUIT & (Z906) GROUND CIRCUIT FUNCTION 
    Fig 3: Probing Blower Motor High Speed Circuit
    GC0043271Courtesy of CHRYSLER LLC

    Remove the jumper from the Blower Motor harness connector.

    Turn the blower control on.

    NOTE: The test light should be illuminated and bright. Compared the brightness to that of a direct connection to the battery.

    Using a 12-volt test light connected to 12 volts, probe the (C70) Blower Motor High Speed circuit in the Blower Motor harness connector.

    Does the test light illuminate brightly? 

    Yes 

    1. Go to  5).

    No 

    1. Repair the (C70) Blower Motor High Speed circuit/(Z906) Ground circuit for high resistance.
    2. Perform BODY VERIFICATION TEST - VER 1 .
  5. 5) CHECK THE OUTPUT FROM THE TIPM ON THE (C7) BLOWER MOTOR CONTROL CIRCUIT 
    Fig 4: Probing Blower Motor Control Circuit
    GC0043272Courtesy of CHRYSLER LLC

    Reconnect the TIPM C8 harness connector.

    Turn the ignition on.

    With the scan tool in TIPM, select Actuators and actuate the Blower Motor.

    Using the 12-volt test light connected to ground, probe the (C7) Blower Motor Control circuit in the Blower Motor harness connector.

    Does the test light illuminate brightly? 

    Yes 

    1. Go to  6).

    No 

    1. Replace the TIPM in accordance with the Service Information.
    2. Perform BODY VERIFICATION TEST - VER 1 .
  6. 6) CHECK FOR A BLOCKAGE STALLING THE BLOWER MOTOR 

    Turn the ignition off.

    Remove the blower motor from the HVAC housing assembly.

    Look for anything on the blower motor and in the HVAC housing that is physically preventing blower motor operation.

    Is anything physically preventing blower operation? 

    Yes 

    1. Repair as necessary. Also, check blower motor for proper operation. Reinstall or replace the blower motor as necessary in accordance with the Service Information.
    2. Perform BODY VERIFICATION TEST - VER 1 .

    No 

    1. Replace the blower motor in accordance with the Service Information.
    2. Perform BODY VERIFICATION TEST - VER 1 .