Removal

  1. Move top to the down position
  2. Disconnect battery negative terminal.
  3. Remove rear seat cushion and rear seat back.
  4. Disconnect pump wire connector connection. See Fig 1.
  5. Remove motor from floor panel. Holding motor assembly with reservoir up, squeeze fill plug to release any air pressure from system.
  6. Mark connections and disconnect hydraulic lines from pump.
  7. Remove motor pump assembly from vehicle.
Fig 1: Hydraulic Pump Assembly
GC0031322Courtesy of DAIMLERCHRYSLER CORP.
1 - HYDRAULIC LINES
2 - MOUNTING BRACKET
3 - HYDRAULIC PUMP ASSEMBLY