Diagnostic Procedure
FRONT BLOWER RELAY OPEN SYMPTOM CHART
| TEST | ACTION | APPLICABILITY |
|---|---|---|
| 1 | Turn the ignition off. Remove the Front Blower Relay from the IPM. Using a 12-volt test light connected to ground, probe cavity 85 of the blower relay connector. Is the test light illuminated? Yes --> Go To 2 No --> Check the B+ feed to the Integrated Power Module (IPM) for an open. If OK, replace the IPM in accordance with the Service Information. Perform BODY VERIFICATION TEST - VER 1 . |
All |
| 2 | Turn the ignition off. Install a substitute relay in place of the existing Front Blower Relay. Turn the ignition on. With the DRBIII®, erase DTCs. Turn the ignition off. With the DRBIII®, read IPM DTCs. Does the DRBIII® display: FRONT BLOWER RELAY OPEN? Yes --> Replace the Integrated Power Module (IPM) in accordance with the Service Information. Perform BODY VERIFICATION TEST - VER 1 . No --> Replace the original Front Blower Relay in accordance with the Service Information. Perform BODY VERIFICATION TEST - VER 1 . |
All |