DTC 9915: Trunk Latch Locked Signal Circuit Open: Notes
- When Monitored: Continuously, with the ignition on.
- Set Condition: When the Power Top Control Module (PTCM) senses the Trunk Latch Unlocked signal is not active and the control module senses B(+) on the Trunk Latch Locked circuit.
| Possible Causes |
|---|
| OPEN TRUNK LATCH LOCKED CIRCUIT |
| OPEN TRUNK LATCH ASSEMBLY GROUND CIRCUIT |
| TRUNK LATCH ASSEMBLY |
| POWER TOP CONTROL MODULE |
Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding.