Home >> Chrysler >> 2004 >> Sebring LXi, 2D Convertible >> Repair and Diagnosis >> Accessories & Equipment >> Communication Devices >> Powertrain Diagnostic Procedures - NGC DRIVEABILITY Symptoms, NGC DRIVEABILITY Diagnostic Tests DTCS P0016 To P0461 - Except Coupe >> DRIVEABILITY - NGC - Diagnostic Tests >> DTC P0442: EVAP System Medium Leak, P0455: EVAP System Large Leak >> When Monitored and Set Condition: >> P0442-EVAP System Medium Leak

P0442-EVAP System Medium Leak

When Monitored: Engine Running. Cold start test. Fuel Level greater than 12%. Ambient Temperature between 4°C and 32°C (39°F and 89°F) Close Loop fuel system. Test runs when small leak test is maturing.

Set Condition: The PCM activates the EVAP Purge Solenoid to pull the EVAP system into a vacuum to close the NVLD switch. Once the NVLD switch is closed, the PCM turns the EVAP Purge solenoid off to seal the EVAP system. If the NVLD switch reopens before the calibrated amount of time for a Medium leak an error is detected. Two Trip Fault.