LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2004 >> Pacifica AWD >> Repair and Diagnosis >> Engine Performance >> System >> Powertrain Diagnostic Procedures >> Diagnostic Procedures >> DRIVEABILITY - NGC - Diagnostic Tests >> P2302-Ignition Coil #1 Secondary Circuit-Insufficient Ionization, P2305-Ignition Coil #2 Secondary Circuit-Insufficient Ionization, P2308-Ignition Coil #3 Secondary Circuit-Insufficient Ionization, P2311-Ignition Coil #4 Secondary Circuit-Insufficient Ionization, P2314-Ignition Coil #5 Secondary Circuit-Insufficient Ionization, P2317-Ignition Coil #6 Secondary Circuit-Insufficient Ionization >> When Monitored and Set Condition:

When Monitored and Set Condition:

P2302-IGNITION COIL #1 SECONDARY CIRCUIT-INSUFFICIENT IONIZATION 

When Monitored: Engine Running.

Set Condition: If PCM detects that the secondary ignition burn time is incorrect or not present an error is detected. One Trip Fault.

P2305-IGNITION COIL #2 SECONDARY CIRCUIT-INSUFFICIENT IONIZATION 

When Monitored: Engine Running.

Set Condition: If PCM detects that the secondary ignition burn time is incorrect or not present an error is detected. One Trip Fault.

P2308-IGNITION COIL #3 SECONDARY CIRCUIT-INSUFFICIENT IONIZATION 

When Monitored: Engine Running.

Set Condition: If PCM detects that the secondary ignition burn time is incorrect or not present an error is detected. One Trip Fault.

P2311-IGNITION COIL #4 SECONDARY CIRCUIT-INSUFFICIENT IONIZATION 

When Monitored: Engine Running.

Set Condition: If PCM detects that the secondary ignition burn time is incorrect or not present an error is detected. One Trip Fault.

P2314-IGNITION COIL #5 SECONDARY CIRCUIT-INSUFFICIENT IONIZATION 

When Monitored: Engine Running.

Set Condition: If PCM detects that the secondary ignition burn time is incorrect or not present an error is detected. One Trip Fault. 

P2317-IGNITION COIL #6 SECONDARY CIRCUIT-INSUFFICIENT IONIZATION 

When Monitored: Engine Running.

Set Condition: If PCM detects that the secondary ignition burn time is incorrect or not present an error is detected. One Trip Fault.