Diagnostic Procedure
RECIRC DOOR TRAVEL TOO SMALL (ACTIVE) - DIAGNOSTIC PROCEDURE
| TEST | ACTION | APPLICABILITY |
|---|---|---|
| 1 | Turn the ignition on. With the DRBIII®, read the active ATC DTCs. Does the DRBIII® display: RECIRC DOOR NOT RESPONDING?
|
All |
| 2 | Turn the ignition off. Disconnect the Recirculation Door Actuator harness connector. Connect a 12-volt Test Light between the Recirculation Door Actuator harness connector cavities. Turn the ignition on. While monitoring the test light, press the RECIRC mode switch from off to on.
NOTE:
Observe test light for approximately 30 seconds. Does the test light start to flash and stay flashing?
|
All |
| 3 | Remove the Recirculation Door Actuator from the A/C-Heater Housing assembly. Rotate the recirculation door from stop to stop. Note: The door should rotate approximately 45 degrees from stop to stop. Does the recirculation door move smoothly in both directions?
|
All |