Diagnostic Procedure
FRONT BLOWER RELAY OPEN - DIAGNOSTIC PROCEDURE
| TEST | ACTION | APPLICABILITY |
|---|---|---|
| 1 | Turn the ignition off. Remove the Front Blower Relay from the IPM. Using a 12-volt test light connected to ground, probe cavity 85 of the blower relay connector. Is the test light illuminated?
|
All |
| 2 | Turn the ignition off. Install a substitute relay in place of the existing Front Blower Relay. Turn the ignition on. With the DRBIII®, erase DTCs. Turn the ignition off. With the DRBIII®, read IPM DTCs. Does the DRBIII® display: FRONT BLOWER RELAY OPEN?
|
All |