Diagnostic Procedure
*NO RESPONSE FROM POWER LIFTGATE MODULE - DIAGNOSTIC PROCEDURE
| TEST | ACTION | APPLICABILITY |
|---|---|---|
| 1 | Turn the ignition on. With the DRBIII®, enter Body then Body Computer.
NOTE:
If communications can be established, check for any liftgate wake up circuit related DTCs. If any are set, perform those related DTCs before proceeding. Was the DRBIII® able to I/D or communicate with the BCM?
|
All |
| 2 | Turn the ignition off. Disconnect the Power Liftgate Module C1 harness connector. Measure the voltage of the Fused B(+) circuit. Is the voltage above 10.0 volts?
|
All |
| 3 | Turn the ignition off. Disconnect the Power Liftgate Module C1 harness connector. Using a 12-volt test light connected to 12-volts, check the Ground circuit. Does the test light illuminate brightly?
|
All |
| 4 |
NOTE:
Ensure there is PCI Bus communication with other modules on the vehicle before proceeding. If not, SYMPTOM LIST from the menu and repair as necessary. Disconnect the Power Liftgate Module C2 harness connector.Use Scope input cable CH7058, Cable to Probe adapter CH7062, and the red and black test probes.Connect the scope input cable to the channel one connector on the DRB. Attach the red and black leads and the cable to probe adapter to the scope input cable.With the DRBIII® select Pep Module Tools.Select lab scope.Select Live Data.Select 12 volt square wave.Press F2 for Scope.Press F2 and use the down arrow to set voltage range to 20 volts. Press F2 again when complete.Connect the Black lead to the chassis ground. Connect the Red lead to the PCI Bus circuit in the Power Liftgate Module C2 connector.Turn the ignition on. Observe the voltage display on the DRBIII® Lab Scope.Does the voltage pulse from 0 to approximately 7.5 volts?
|
All |
| 5 | Disconnect the BCM C3 harness connector Measure the voltage between the Liftgate Module Wake Up Signal circuit and ground. Is the voltage above 10.0 volts?
|
All |
| 6 | Disconnect the Body Control Module C3 harness connector. Disconnect the Power Liftgate Module C2 harness connector. Measure the resistance of the Liftgate Module Wake Up Signal circuit between the BCM C3 connector and the Power Liftgate Module C2 connector. Is the resistance below 5.0 ohms?
|
All |
| 7 | Disconnect the Body Control Module C3 harness connector. Disconnect the Power Liftgate Module C2 harness connector. Measure the resistance between the Liftgate Module Wake Up Signal circuit and ground. Is the resistance below 100.0 ohms?
|
All |
| 8 | If there are no possible causes remaining, view repair.
|
All |