Home >> Chrysler >> 2004 >> Pacifica AWD >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Body Diagnostic Procedures - Communication, Door Ajar, Electrically Heated Systems, Exterior Lighting >> Communication >> Symptom: *NO RESPONSE FROM NAVIGATION MODULE >> Diagnostic Procedure

Diagnostic Procedure

*NO RESPONSE FROM NAVIGATION MODULE - DIAGNOSTIC PROCEDURE

TEST ACTION APPLICABILITY
1 Turn the ignition on.
With the DRBIII®, attempt to communicate with the Instrument Cluster.
Was the DRBIII® able to I/D or communicate with the Instrument Cluster?
  1. Yes: Go To 2
  2. No: SYMPTOM LIST for problems related to no communication with the Instrument Cluster.

    Perform BODY VERIFICATION TEST VER-1 .

All
2 Turn the ignition off.
Disconnect the Navigation Module harness connector.
Using a 12-volt test light connected to 12-volts, probe the ground circuit.
Is the test light illuminated?
  1. Yes: Go To 3
  2. No: Repair the ground circuit for an open.

    Perform BODY VERIFICATION TEST VER-1 .

All
3 Turn the ignition off.
Disconnect the Navigation Module harness connector.
Using a 12-volt test light connected to ground, probe the Fused B(+) circuit.
Is the test light illuminated?
  1. Yes: Go To 4
  2. No: Check IPM fuse #48 for an open. If OK, repair the Fused B+ circuit for an open.

    Perform BODY VERIFICATION TEST VER-1 .

All
4 Turn the ignition off.
Disconnect the Navigation Module harness connector.
Turn the ignition on.
Using a 12-volt test light connected to ground, probe the Fused Accessory Relay Output circuit.
Is the test light illuminated?
  1. Yes: Go To 5
  2. No: Check IPM fuse #25 for an open. If OK, repair the Fused Accessory Relay Output circuit for an open.

    Perform BODY VERIFICATION TEST VER-1 .

All
5
NOTE: Ensure there is PCI Bus communication with other modules on the vehicle before proceeding. If not, SYMPTOM LIST from the menu and repair as necessary.
Disconnect the Navigation Module harness connector.Use Scope input cable CH7058, Cable to Probe adapter CH7062, and the red and black test probes.Connect the scope input cable to the channel one connector on the DRB. Attach the red and black leads and the cable to probe adapter to the scope input cable.With the DRBIII® select Pep Module Tools.Select lab scope.Select Live Data.Select 12 volt square wave.Press F2 for Scope.Press F2 and use the down arrow to set voltage range to 20 volts. Press F2 again when complete.Connect the Black lead to the chassis ground. Connect the Red lead to the PCI Bus circuit in the Navigation Module connector.Turn the ignition on.Observe the voltage display on the DRBIII® Lab Scope.Does the voltage pulse from 0 to approximately 7.5 volts?
  1. Yes: Replace the Navigation Module in accordance with the Service Information.

    Perform BODY VERIFICATION TEST VER-1 .

  2. No: Repair the PCI Bus circuit for an open.

    Perform BODY VERIFICATION TEST VER-1 .

All