Pretest Inspection & Diagnostic Procedure
Following precautions and procedures must be followed:
- Always follow air bag service precautions to avoid air bag deployment and possible personal injury. See AIR BAG SAFETY PRECAUTIONS .
- After component replacement, ensure proper system operation. See SYSTEM OPERATION CHECK .
- When testing voltage or continuity at ORC, use terminal side (not wire end) of connector. DO NOT probe wire through insulation.
- Always check any Technical Service Bulletins (TSBs) that apply to vehicle.
- When using diagnostic charts, DO NOT skip any steps in chart or incorrect diagnosis may result. Always start procedure at TEST 1A: IDENTIFYING SYSTEM PROBLEMS . Starting with any other test may result in incorrect diagnosis. Always perform SYSTEM OPERATION CHECK after repairs are made.
- Always use most current DRB diagnostic program cartridge available to prevent erroneous DTCs or test results.
- When using diagnostic charts, use DRB voltmeter unless instructed to use an external voltmeter or test light.
- When performing electrical tests, prevent accidental shorting of terminals. Such shorts can damage fuses or components and may cause a second DTC to be set, making diagnosis of original problem more difficult.
- Vehicle must have a fully-charged battery and functional charging system.
- Each time a connector is disconnected, inspect it to ensure it is in good condition. Always focus on circuit being tested. Dirt, water and corrosion, are most common problems in connectors.
- Always disconnect DRB after use.
- Always disconnect DRB before charging battery.