Monitor & Set Conditions
DTC is monitored with engine running. BCM reads signal from HVAC control panel for mode request signal and positions mode door accordingly. DTC will set if voltage reading on mode door request signal circuit exceeds 90% of ignition voltage. When DTC is set, BCM will place mode door in default position.