LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2001 >> Sebring LX, 2D Convertible >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Manual HVAC Systems - Except Coupe >> Diagnostic Tests >> Test Q: Mode Door Input Open/Shorted To Ground >> Monitor & Set Conditions

Monitor & Set Conditions

Monitored with ignition switch in ON position. HVAC control panel provides a 5-volt pull-up signal to mode request selector. BCM reads pull-up signal from HVAC mode request and positions mode door accordingly. DTC will set when voltage on pull-up signal circuit is less than 0.1 volt. When DTC is set, BCM will place mode door in a default position.