Monitor & Set Conditions
Monitored with ignition switch in ON position. DTC/fault message will set when BCM detects voltage less than 0.06 voltor greater than 4.8 volts in evaporator temperature sensor signal input at BCM C2 connector terminal No. 9 (Light Green/Black wire).