Home >> Chrysler >> 2001 >> Sebring LX, 2D Convertible >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Manual HVAC Systems - Except Coupe >> Diagnostic Tests >> Test N: Common Output Shorted To Ground >> Monitor & Set Conditions

Monitor & Set Conditions

Monitored whenever BCM attempts to move any HVAC housing actuator door. DTC will set when BCM detects a short to ground in blend door driver, mode door driver, recirculation door driver or common door driver circuits.