Monitor & Set Conditions
DTC is monitored with engine running. BCM reads blend door feedback signal from HVAC control panel. DTC will set if BCM detects less than 0.06 volt or 4.8 volts or more on blend door feedback signal circuit (Red/White wire). When DTC is set, BCM will place blend door in a default position.