A/T Control Relay
WARNING: This page is about a different variant/trim than selected.
NOTE:
For circuit reference, see CONNECTOR IDENTIFICATION
and WIRING DIAGRAMS
.
Remove A/T control relay. See Figure . Using fused jumper wires, connect relay terminals No. 2 to battery negative, and terminal No. 4 to battery positive. See Fig 1 . Ensure continuity is present between relay terminals No. 1 and 3. Continuity should not be present with jumper wires removed. Replace relay if continuity is not as specified.