Home >> Chrysler >> 2001 >> Sebring LX, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 40 (Simplified Wiring System (SWS) - Coupe) >> SWS Diagnosis >> Symptom Procedures >> INSPECTION PROCEDURE C-7: Central Door Locking System: Rolling lock function does not operate. >> Diagnosis

INSPECTION PROCEDURE C-7: Central Door Locking System: Rolling lock function does not operate.: Diagnosis

WARNING: This page is about a different car, the 2005 Dodge Stratus and 2005 Chrysler Sebring. However, it is still accessible from the selected car via links, so may be relevant.

Required Special Tools: 

  1. STEP 1. Check method of the input signal 

    Q: Which is to be used, the scan tool or a voltmeter to check the input signal? 

    Scan tool MB991502  : Go to Step 2.

    Voltmeter  : Go to  Step 3.

  2. STEP 2. Check the input signal (by using scan tool MB991502). 

    Check the input signals from the following switches:

    • Ignition switch (IG1)
    • Driver's and passenger's door switch
    • Driver's and passenger's door lock actuator switch
    • Speed sensor
    CAUTION: To prevent damage to scan tool MB991502, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool MB991502.
    1. Connect scan tool MB991502 to the data link connector.
    2. Check that the tone alarm of scan tool MB991502 sounds when the input signal enters.

    Q: Does the tone alarm of scan tool MB991502 sound when the input signal enters? 

    YES  : Replace the ETACS-ECU. The rolling lock function should work normally.

    NO  :

  3. STEP 3. Check the input signal (by using a voltmeter). 

    Check the input signals from the following switches:

    • Ignition switch (IG1)
    • Driver's and passenger's door switch
    • Driver's and passenger's door lock actuator switch
    • Speed sensor
    1. Use special tool MB991529 to connect a voltmeter between ground terminal 4 or 5 and ETACS-ECU terminal 9 of the data link connector.
    2. Check that the voltmeter indicator deflects once when the input signal enters.

    Q: Does the voltmeter indicator deflect? 

    YES  : Replace the ETACS-ECU. The rolling lock function should work normally.