LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2001 >> Sebring LX, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 33 (Starting System - Coupe) >> Starter Motor Assembly >> Inspection >> Free Running Test

Free Running Test

WARNING: This page is about a different car, the 2005 Dodge Stratus and 2005 Chrysler Sebring. However, it is still accessible from the selected car via links, so may be relevant.
  1. Place the starter motor in a vise equipped with soft jaws and connect a fully-charged 12-volt battery to the starter motor as follows:
  2. Connect a test ammeter (100-ampere scale) and carbon pile rheostat in series between the positive battery terminal and starter motor terminal.
  3. Connect a voltmeter (15-volt scale) across the starter motor.
  4. Rotate carbon pile to full-resistance position.
  5. Connect the battery cable from the negative battery terminal to the starter motor body.
  6. Adjust the rheostat until the battery positive voltage shown by the voltmeter is 11 V.
  7. Confirm that the maximum amperage is within the specifications and that the starter motor turns smoothly and freely.

    Current: maximum 90 Amps 

    Fig 1: Connecting Voltmeter Across The Starter Motor (2.4L Engine)
    G04537396Courtesy of DAIMLERCHRYSLER CORPORATION
    Fig 2: Connecting Voltmeter Across The Starter Motor (3.0L Engine)
    G04537397Courtesy of DAIMLERCHRYSLER CORPORATION