Low Side Pressure Is Low & High Side Pressure Is High
Some possible causes of low side system pressure being to low and high side system pressure being to high include:
- Restricted refrigerant flow through refrigerant lines.
- Restricted refrigerant flow through expansion valve.
- Restricted refrigerant flow through fixed orifice tube.
- Restricted refrigerant flow through receiver-drier.
- Restricted refrigerant flow through condenser.