Removal & Installation: Thermostat: Installation
Install thermostat so that bleed valve is pointing up. See Fig 2. Ensure not to damage "O" ring when installing thermostat. Ensure "O" ring does not come in contact with oil. To complete installation, reverse removal procedure. Tighten all fasteners to specification. See TORQUE SPECIFICATIONS .