Fastener Specifications
Air Conditioning Wiring Harness
| Callout | Component Name [Component Quantity] | Single Use Fastener/Component | Thread Locking Adhesive Required | Specification | Procedure |
|---|---|---|---|---|---|
| Metric (English) | |||||
| 1 | Heater and Air Conditioning Evaporator and Blower Module Bolt | - | - | 1.3 N.m (12 lb in) | Air Conditioning Wiring Harness Replacement (C68) |
Air Inlet Valve Actuator
| Callout | Component Name [Component Quantity] | Single Use Fastener/Component | Thread Locking Adhesive Required | Specification | Procedure |
|---|---|---|---|---|---|
| Metric (English) | |||||
| 1 | Heater and Air Conditioning Evaporator and Blower Module Bolt [2x] | - | - | 1.3 N.m (12 lb in) | Air Inlet Valve Actuator Replacement (C68) |
Heater and Air Conditioning Remote Control
| Callout | Component Name [Component Quantity] | Single Use Fastener/Component | Thread Locking Adhesive Required | Specification | Procedure |
|---|---|---|---|---|---|
| Metric (English) | |||||
| 1 | Heater and Air Conditioning Remote Control Bracket Screw [3x] | - | - | 5 N.m (44 lb in) | Heater and Air Conditioning Remote Control Replacement (C68 & URO) , or Heater and Air Conditioning Remote Control Replacement (C68 & UDC) |
Heater and Air Conditioning User Interface Control
| Callout | Component Name [Component Quantity] | Single Use Fastener/Component | Thread Locking Adhesive Required | Specification | Procedure |
|---|---|---|---|---|---|
| Metric (English) | |||||
| 1 | Heater and Air Conditioning User Interface Control Bolt [2x] | - | - | 2.5 N.m (22 lb in) | Heater and Air Conditioning User Interface Control Replacement |
Mode Control Cam
| Callout | Component Name [Component Quantity] | Single Use Fastener/Component | Thread Locking Adhesive Required | Specification | Procedure |
|---|---|---|---|---|---|
| Metric (English) | |||||
| 1 | Heater and Air Conditioning Remote Control Bracket Screw [3x] | - | - | 1.3 N.m (12 lb in) | Mode Control Cam Replacement (C68) |
Mode Valve Actuator
| Callout | Component Name [Component Quantity] | Single Use Fastener/Component | Thread Locking Adhesive Required | Specification | Procedure |
|---|---|---|---|---|---|
| Metric (English) | |||||
| 1 | Heater and Air Conditioning Evaporator and Blower Module Bolt [2x] | - | - | 1.3 N.m (12 lb in) | Mode Valve Actuator Replacement (C68) |
Temperature Valve Actuator
| Callout | Component Name [Component Quantity] | Single Use Fastener/Component | Thread Locking Adhesive Required | Specification | Procedure |
|---|---|---|---|---|---|
| Metric (English) | |||||
| 1 | Heater and Air Conditioning Evaporator and Blower Module Bolt [2x] | - | - | 1.3 N.m (12 lb in) | Temperature Valve Actuator Replacement (C68 & URO) , or Temperature Valve Actuator Replacement (C68 & UDC) |