LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2024 >> Traverse LS, FWD >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Displays And Gauges >> Diagnostic Information and Procedures >> Outside Air Temperature Display Malfunction >> Conditions for Setting the DTC

Conditions for Setting the DTC

P0071 

The difference between the following parameters is greater than a predefined value: Ambient Air Temperature Sensor Signal & Air Conditioning High Side Pressure Switch Signal = Greater than 25°C (77°F)

P0072 

Ambient Air Temperature Sensor Signal = Greater than 88°C (190°F)

P0073 

Ambient Air Temperature Sensor Signal = Less than -40°C (-40°F)

P0074 

Ambient Air Temperature Sensor Signal = Intermittent