Installation Procedure
Automatic Transmission Fluid Pump Seal (3) - Install NEW
- Automatic Transmission Fluid Filter (2) - Install
- Automatic Transmission Fluid Filter Bolt (1) - Install NEW and tighten [2x] - Fastener Specifications
Automatic Transmission Fluid Pan Gasket (3) - Install
- Automatic Transmission Fluid Pan (2) - Install
- Automatic Transmission Fluid Pan Bolt (1) - Install and tighten in sequence [16x] - Fastener Specifications
Exhaust System Seal-Right Side (1) - Install NEW
Exhaust System Seal-Left Side (1) - Install NEW
- Raise and support the exhaust system as necessary.
Exhaust Front Pipe Nut- Right Side (1) - Install and tighten [3x] - Fastener Specifications
Exhaust Front Pipe Nut- Left Side (1) - Install and tighten [3x] - Fastener Specifications
Exhaust Front Pipe Heat Shield (2) - Install
- Exhaust Heat Shield Bolt (1) - Install and tighten - Fastener Specifications
Exhaust Front Pipe Heat Shield (2) - Install
- Exhaust Heat Shield Bolt (1) - Install and tighten - Fastener Specifications
- CAUTION:
Refer to Component Fastener Tightening Caution .
NOTE:A special anti-seize compound is used in the HO2S threads. The compound consists of liquid graphite and glass beads. The graphite tends to burn away, but the glass beads remain, making the sensor easier to remove. New, or service replacement sensors already have the compound applied to the threads. If the sensor is removed from an exhaust component and if for any reason the sensor is to be reinstalled, the threads must have anti-seize compound applied before reinstallation. Adhesives, Fluids, Lubricants, and Sealers
Using a suitable tool, install and tighten the heated oxygen sensor - bank 2 sensor 2 (1). Fastener Specifications
- Electrical Connector@Heated Oxygen Sensor- Bank 2 Sensor 2 - Connect
Using a suitable tool, install and tighten the heated oxygen sensor - bank 2 sensor 1 (1). Fastener Specifications
- Electrical Connector@Heated Oxygen Sensor- Bank 2 Sensor 1 - Connect
Using a suitable tool, install and tighten the heated oxygen sensor - bank 1 sensor 2 (1). Fastener Specifications
- Electrical Connector@Heated Oxygen Sensor- Bank 1 Sensor 2 - Connect
Using a suitable tool, install and tighten the heated oxygen sensor - bank 1 sensor 1 (1). Fastener Specifications
- Electrical Connector@Heated Oxygen Sensor- Bank 1 Sensor 1 - Connect
- Front Wheelhouse Liner- Left Side and Right Side - Install - Front Wheelhouse Liner Replacement
- Inspect the exhaust system for leaks.
- Remove the drain pan.
- Fill the transmission to the proper level with NEW transmission fluid. Transmission Fluid Level and Condition Check
- Remove the support and lower the vehicle.
Refer to Fastener Caution .