Typical Scan Tool Data
WARNING: This page is about a different variant/trim than selected.
Fuel Pump Motor Control Circuit High Test Status
| Circuit | Short to Ground | Open | Short to Voltage | Control Circuit Shorted to Control Circuit |
|---|---|---|---|---|
| Operating Conditions:
Ignition = On Parameter Normal Range: Not Run/Okay |
||||
| Control - Terminal 1 | Not Run/Okay | Not Run/Okay | Malfunction | Not Run/Okay |
| Control - Terminal 2 | Not Run/Okay | Not Run/Okay | Malfunction | Not Run/Okay |
| Control - Terminal 3 | Not Run/Okay | Not Run/Okay | Malfunction | Not Run/Okay |
Fuel Pump Motor Control Circuit Low Test Status
| Circuit | Short to Ground | Open | Short to Voltage | Control Circuit Shorted to Control Circuit |
|---|---|---|---|---|
| Operating Conditions:
Ignition = On Parameter Normal Range: Not Run/Okay |
||||
| Control - Terminal 1 | Malfunction | Not Run/Okay | Not Run/Okay | Not Run/Okay |
| Control - Terminal 2 | Malfunction | Not Run/Okay | Not Run/Okay | Not Run/Okay |
| Control - Terminal 3 | Malfunction | Not Run/Okay | Not Run/Okay | Not Run/Okay |
Fuel Pump Motor Control Circuit Open Test Status
| Circuit | Short to Ground | Open | Short to Voltage | Control Circuit Shorted to Control Circuit |
|---|---|---|---|---|
| Operating Conditions:
Ignition = On Parameter Normal Range: Not Run/Okay |
||||
| Control - Terminal 1 | Not Run/Okay | Malfunction | Not Run/Okay | Not Run/Okay |
| Control - Terminal 2 | Not Run/Okay | Malfunction | Not Run/Okay | Not Run/Okay |
| Control - Terminal 3 | Not Run/Okay | Malfunction | Not Run/Okay | Not Run/Okay |