Conditions for Running the DTC
WARNING: This page is about a different variant/trim than selected.
P0475, P0478, P10C0, P10EB
- M64 Starter = Inactive
- {P0475} M122 Exhaust Pressure Control Valve Actuator = Off
- {P0478, P10C0, P10EB} M122 Exhaust Pressure Control Valve Actuator = On
- Ignition and Start Signal = Greater than 11 V
- {P0475} Valve@M122 Exhaust Pressure Control Valve Actuator = Full Open
Frequency the DTC runs = Continuously - After the running conditions are met
P2B98, P2B99
- M64 Starter = Inactive
- Ignition and Start Signal = Greater than 11 V
Frequency the DTC runs = Continuously - After the running conditions are met