Typical Scan Tool Data
WARNING: This page is about a different variant/trim than selected.
Barometric Pressure Sensor 2
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Ignition = On & Engine = Off Parameter Normal Range: 56 to 105 kPa (8 to 15 PSI) |
|||
| Ignition | 255 kPa (37 PSI) | 255 kPa (37 PSI) | - |
| Serial Data | 255 kPa (37 PSI) | 255 kPa (37 PSI) | 255 kPa (37 PSI) |
| Ground | - | 255 kPa (37 PSI) | - |