Diagnostic Fault Information
WARNING: This page is about a different variant/trim than selected.
| Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
|---|---|---|---|---|
| 5 V Reference | P018C, P1002, P1177, P129B | P018C | P1002, P1177, P129B | P018B |
| Signal | P018C | P018C, P2635 | P018D* | P018B |
| Low Reference | - | P018D | * | P018B |
| *Internal control module or component damage may occur if the circuit shorts to B+. | ||||