Conditions for Setting the DTC
WARNING: This page is about a different variant/trim than selected.
P0181
Fuel Temperature Sensor & ECT Sensor = Not within 20°C (36°F) of each other - For greater than 2 s
P0182
Fuel Temperature Sensor = Warmer than 149°C (301°F) - For greater than 2 s
P0183
Fuel Temperature Sensor = Colder than -39°C (-38°F) - For greater than 2 s
P0184
Fuel Temperature Sensor = The signal is intermittent or changes too fast. - For less than 2 s