Circuit/System Testing
WARNING: This page is about a different variant/trim than selected.
- Engine - Idling - At normal operating temperature
- Verify the scan tool parameter: Mass Airflow Sensor = 5 to 40 g/s
- If less than 5 g/s
Verify the following conditions do not exist:
- Induction System - Leaking/Restricted - Refer to: Component/System Leak Test
- If a condition exists
Repair or replace as necessary
- If no condition exists
Perform the scan tool function: Particulate Filter Service Regeneration
- If a condition exists
- If greater than 40 g/s
Verify the following conditions do not exist:
- Induction System - Leaking - Refer to: Component/System Leak Test
- If a condition exists
Repair or replace as necessary
- Go to next step: If no condition exists
Go to next step: Refer to step 3
- If a condition exists
- Go to next step: If between 5 and 40 g/s
- If less than 5 g/s
- Ignition/Vehicle - Off
- Verify a condition does not exist with the component:
- Exhaust System - LeakingRefer to: Symptoms - Engine Exhaust
- If a condition exists
Repair or replace as necessary
- Go to next step: If no condition exists
- Perform the following procedure/test: Cylinder Power Balance Test
- If the procedure/test does not pass
Repair as necessary
- Go to next step: If the procedure/test passes
- If the procedure/test does not pass
- Replace the component: B195A Nitrogen Oxides Sensor 1