Component Testing
WARNING: This page is about a different variant/trim than selected.
- Ignition/Vehicle - Off
- Disconnect the appropriate electrical connector:
- B193A Charge Air Cooler Air Temperature Sensor - Inlet
- B193B Charge Air Cooler Air Temperature Sensor - Outlet
- Test for 200 to 114, 900 ohms between the test points: Signal terminal 2 & Low Reference terminal 1
- If not between 200 and 114, 900 ohms
Replace the component: B193A Charge Air Cooler Air Temperature Sensor - InletorB193B Charge Air Cooler Air Temperature Sensor - Outlet
- Go to next step: If between 200 and 114, 900 ohms
- If not between 200 and 114, 900 ohms
- Verify the value is within the range listed in the table: Temperature Versus Resistance - Charge Air Cooler Temperature Sensor (B193A Charge Air Cooler Air Temperature Sensor - Inlet and B193B Charge Air Cooler Air Temperature Sensor - Outlet)
, or Temperature Versus Resistance - Charge Air Cooler Temperature Sensor (B34K Charge Air Cooler Coolant Temperature Sensor - Inlet)
- If not in the specified range
Replace the component: B193A Charge Air Cooler Air Temperature Sensor - InletorB193B Charge Air Cooler Air Temperature Sensor - Outlet
- Go to next step: If in the specified range
- If not in the specified range
- Test for infinite resistance between the test points: Each terminal of the component & The component's housing
- If less than infinite resistance
Replace the component: B193A Charge Air Cooler Air Temperature Sensor - InletorB193B Charge Air Cooler Air Temperature Sensor - Outlet
- Go to next step: If infinite resistance
- If less than infinite resistance
- All OK.