Cleaning and Inspection Procedure - Required
WARNING: This page is about a different variant/trim than selected.
Inspect the charge air cooler outlet air hose (2) :
- Use dish soap and water to clean the inside of the charge air cooler outlet air hose (2). Clean the interior of the hose, and allow to completely dry. Ensure any oil residue is removed from the hose internal interface surfaces.
- Inspect the interior of the charge air cooler outlet air hose (2) for tears or delamination. Replace the hose if damage is found.
- Inspect the charge air cooler outlet air hose clamps (1). Replace the charge air cooler outlet air hose (2) if damage is found or the clamp components are missing.
- CAUTION:
The glow plug bore MUST be cleaned prior to glow plug installation. If the glow plug bore is not cleaned of carbon buildup prior to glow plug installation, it may cause severe damage to the glow plug. If the glow plug is damaged, the glow plug bore and combustion chamber must be cleaned of all debris, and the glow plug must be replaced.
Using the EN-52074 Glow Plug Bore Reamer (1), clean the glow plug bore. Hole must be free of lubricant and grease.