Crankshaft Bearing Cap Bolt - Inner and Outer Torque Sequence
| Crankshaft Bearing Cap Bolt - Inner and Outer Sequence | |||||
|---|---|---|---|---|---|
| Callout | Component Name [Component Quantity] | Single Use Fastener/Component | Thread Locking Adhesive Required | Specification | Procedure |
| Metric (English) | |||||
| 1 | Crankshaft Bearing Cap Bolt- Inner [10x] | Yes | - | First Pass: 20 N.m (15 lb ft) Final Pass: 110 degrees |
Crankshaft and Bearing Removal and Installation |
| 2 | Crankshaft Bearing Cap Bolt- Outer [10x] | Yes | - | First Pass: 20 N.m (15 lb ft) Final Pass: 80 degrees |
Crankshaft and Bearing Removal and Installation |