Home >> Chevrolet >> 2023 >> Camaro ZL1, 2D Convertible, Standard Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 4 (Automatic Transmission - 10L60, 10L80 Or 10L90 - Specifications) >> Specifications >> Temperature Versus Resistance >> Temperature Versus Resistance - B13 Automatic Transmission Fluid Temperature Sensor

Temperature Versus Resistance - B13 Automatic Transmission Fluid Temperature Sensor

WARNING: This page is about a different variant/trim than selected.
Temperature Resistance
140°C (284°F) 69 to 73 ohms
130°C (266°F) 86 to 90 ohms
120°C (248°F) 110 to 114 ohms
110°C (230°F) 140 to 144 ohms
100°C (212°F) 182 to 186 ohms
95°C (203°F) 211 to 215 ohms
90°C (194°F) 239 to 243 ohms
85°C (185°F) 279 to 283 ohms
80°C (176°F) 318 to 322 ohms
75°C (167°F) 374 to 378 ohms
70°C (158°F) 430 to 434 ohms
65°C (149°F) 509 to 513 ohms
60°C (140°F) 589 to 593 ohms
55°C (131°F) 705 to 709 ohms
50°C (122°F) 821 to 825 ohms
45°C (113°F) 994 to 998 ohms
40°C (104°F) 1.166 k to 1.170 kohms
35°C (95°F) 1.427 k to 1.431 kohms
30°C (86°F) 1.688 k to 1.692 kohms
25°C (77°F) 2.093 k to 2.097 kohms
20°C (68°F) 2.498 k to 2.502 kohms
15°C (59°F) 3.141 k to 3.145 kohms
10°C (50°F) 3.784 k to 3.788 kohms
5°C (23°F) 4.835 k to 4.839 kohms
0°C (32°F) 5.886 k to 5.890 kohms
-5°C (23°F) 7.652 k to 7.656 kohms
-10°C (14°F) 9.418 k to 9.422 kohms
-15°C (5°F) 12.463 k to 12.467 kohms
-20°C (-4°F) 15.509 k to 15.513 kohms
-25°C (-13°F) 20.941 k to 20.945 kohms
-30°C (-22°F) 26.374 k to 26.378 kohms
-35°C (-31°F) 36.431 k to 36.435 kohms
-40°C (-40°F) 46.489 k to 46.493 kohms