Circuit/System Testing
WARNING: This page is about a different variant/trim than selected.
- Ignition/Vehicle & All vehicle systems - Off
- Disconnect the appropriate electrical connector: Q83 Valve Lifter Oil Solenoid Valve
- Ignition - On/Vehicle - In Service Mode
- Verify a test lamp turns On between the test points: Ignition circuit terminal 1 & Ground
- If the test lamp does not turn On and the circuit fuse is OK
- Ignition/Vehicle - Off & Remove - Test lamp
- Test for less than 2 ohms between the test points: Ignition circuit terminal 1 & Output terminal@F63UA Fuse
- If 2 ohms or greater - Repair the open/high resistance in the circuit.
- If less than 2 ohms - Verify the fuse is OK and there is voltage at the fuse.
- If the test lamp does not turn On and the circuit fuse is open
- Ignition/Vehicle - Off & Remove - Test lamp
- Connect the electrical connector: Q83 Valve Lifter Oil Solenoid Valve
- Ignition - On/Vehicle - In Service Mode
- Replace the component: F63UA Fuse
- Verify the fuse does not open.
- If the fuse opens and there are components connected to the circuit - Disconnect a component and repeat procedure starting at step 4.4
- If the fuse opens with all components disconnected from the circuit - Repair the short to ground on the circuit.
- If the fuse does not open after disconnecting a component from the circuit - Replace the component disconnected last.
- Go to next step: If the fuse does not open with all components connected.
- Operate the component: Each component on the circuit - One at a time - Except the following component: Q83 Valve Lifter Oil Solenoid Valve
Verify the fuse does not open when any of the components are activated.
- If the fuse opens - Replace the component that caused the fuse to open when activated.
- Go to next step: If the fuse does not open.
- Refer to: Component Testing - Dynamic Test
NOTE:It may be necessary to use a scan tool control function to operate a component.
- Go to next step: If the test lamp turns On
- Verify a test lamp does not turn On between the test points: Control circuit terminal 2 & B+
- If the test lamp turns On
- Ignition/Vehicle - Off & Remove - Test lamp
- Disconnect the appropriate electrical connector: K20 Engine Control Module
- Test for infinite resistance between the test points: Control circuit terminal 2@Component harness & Ground
- If less than infinite resistance - Repair the short to ground on the circuit.
- If infinite resistance - Replace the component: K20 Engine Control Module
- Go to next step: If the test lamp does not turn On
- Remove - Test Lamp
- Test for 5.6 to 6.2 V between the test points: Control circuit terminal 2 & Ground
- If 5.6 V or less
- Ignition/Vehicle - Off
- Disconnect the appropriate electrical connector: K20 Engine Control Module
- Test for less than 2 ohms between the test points: Control circuit terminal 2@Component harness & The other end of the circuit
- If 2 ohms or greater - Repair the open/high resistance in the circuit.
- If less than 2 ohms - Replace the component: K20 Engine Control Module
- If greater than 6.2 V
- Ignition/Vehicle - Off
- Disconnect the appropriate electrical connector: K20 Engine Control Module
- Ignition - On/Vehicle - In Service Mode
- Test for less than 1 V between the test points: Control circuit terminal 2@Component harness & Ground
- If 1 V or greater - Repair the short to voltage on the circuit.
- If less than 1 V - Replace the component: K20 Engine Control Module
- Go to next step: If between 5.6 and 6.2 V
- Perform the following procedure/test: Component Testing - Static Test & Dynamic Test
Verify the procedure/test passes.
- If the procedure/test does not pass
Replace the component: Q83 Valve Lifter Oil Solenoid Valve
- Go to next step: If the procedure/test passes
- If the procedure/test does not pass
- Replace the component: K20 Engine Control Module