Component Testing
WARNING: This page is about a different variant/trim than selected.
Q40 Turbocharger Bypass Solenoid Valve
- Ignition/Vehicle - Off
- Disconnect the electrical connector: Q40 Turbocharger Bypass Solenoid Valve
- Test for 5 to 15 ohms between the test points: Control terminal 2 & Ignition terminal 1
- If not between 5 and 15 ohms
Replace the component: Q40 Turbocharger Bypass Solenoid Valve
- Go to next step: If infinite resistance
- If not between 5 and 15 ohms
- All OK.
Q42 Turbocharger Wastegate Solenoid Valve
- Ignition/Vehicle - Off
- Disconnect the electrical connector: Q42 Turbocharger Wastegate Solenoid Valve
- Test for 10 to 20 ohms between the test points: Control terminal 2 & Ignition terminal 1
- If not between 10 and 20 ohms
Replace the component: Q42 Turbocharger Wastegate Solenoid Valve
- Go to next step: If between 10 and 20 ohms
- If not between 10 and 20 ohms
- All OK.