X51A Fuse Block - Instrument Panel X1
| - |
Connector Part Information
|
Terminal Part Information
| Terminal Type ID | Terminated Lead | Diagnostic Test Probe | Terminal Removal Tool |
|---|---|---|---|
| I | 19332366 | J-35616-35 (VT) | J-38125-212 |
| II | 19368242 | J-35616-32 (OG) | J-38125-36 |
| III | 19368304 | J-35616-43 (RD) | J-38125-557 |
| Pin | Size | Color | Circuit | Function | Terminal Type ID | Option |
|---|---|---|---|---|---|---|
| F1Y | 0.5 | RD / GN | 5140 | Battery Positive Voltage | I | - |
| F2Y | 0.5 | RD / BU | 5240 | Battery Positive Voltage | I | - |
| F3Y | 0.5 | RD / VT | 5340 | Battery Positive Voltage | I | - |
| F4Y | 0.5 | RD / WH | 5440 | Battery Positive Voltage | I | - |
| F5Y | 0.5 | RD / GY | 5540 | Battery Positive Voltage | I | - |
| F6Y | 0.5 | RD / VT | 5640 | Battery Positive Voltage | I | - |
| F7Y | 0.5 | RD / WH | 5740 | Battery Positive Voltage | I | - |
| F8Y | 1.5 | RD / YE | 5840 | Battery Positive Voltage | I | - |
| F9Y | 0.35 | RD / YE | 5040 | Battery Positive Voltage | I | - |
| F10Y | 0.35 | RD / GN | 1202 | Battery Positive Voltage | I | - |
| F11Y | 0.5 | RD / BN | 5940 | Battery Positive Voltage | I | - |
| F12Y | 0.35 | RD / BN | 440 | Battery Positive Voltage | I | - |
| F13Y | 0.5 | RD / GY | 3540 | Battery Positive Voltage | I | - |
| F14Y | 0.75 | RD / BU | 1240 | Battery Positive Voltage | I | - |
| F18Y | 0.5 | RD / YE | 1142 | Battery Positive Voltage | I | - |
| F19Y | 0.35 | RD / GY | 2840 | Battery Positive Voltage | I | - |
| F20X | 0.5 | YE | 6817 | LED Backlight Dimming Control 1 | I | - |
| F20Y | 0.5 | YE | 6817 | LED Backlight Dimming Control 1 | I | - |
| F21Y | 0.35 | VT | 801 | Retained Accessory Power Control | I | - |
| F22Y | 1 | VT | 1301 | Retained Accessory Power Control | I | - |
| F24X | 2.5 | VT / BN | 341 | Run Ignition 3 Voltage | I | - |
| F24Y | 0.35 | VT / BN | 241 | Run Ignition 3 Voltage | I | - |
| F25X | 2.5 | RD / VT | 6340 | Battery Positive Voltage | I | - |
| F25Y | 0.5 | RD / GN | 742 | Battery Positive Voltage | I | - |
| F26X | 1.5 | VT / GN | 39 | Run/Crank Ignition 1 Voltage | I | - |
| F26Y | 0.5 | VT / BN | 300 | Run Ignition 3 Voltage | I | - |
| F27X | 1.5 | VT / GN | 39 | Run/Crank Ignition 1 Voltage | I | - |
| F27Y | 0.35 0.35 |
VT / GN VT / BK |
1739 3 |
Run/Crank Ignition 1 Voltage Run/Crank Ignition 1 Voltage |
I I |
UEU -UEU |
| F28X | 1.5 | VT / GN | 39 | Run/Crank Ignition 1 Voltage | I | - |
| F28Y | 0.75 | VT / BN | 441 | Run Ignition 3 Voltage | I | - |
| F30X | 2.5 | RD / GN | 2173 | 12V Regulated Supply Voltage 2 | I | - |
| F30Y | 1 | RD / VT | 340 | Battery Positive Voltage | I | - |
| F31X | 2.5 | RD / VT | 6340 | Battery Positive Voltage | I | - |
| F31Y | 0.35 | RD / BU | 302 | Battery Positive Voltage | I | - |
| F32X | 2.5 | RD / VT | 6340 | Battery Positive Voltage | I | - |
| F32Y | 1 | RD / GY | 642 | Battery Positive Voltage | I | IOR |
| F33Y | 0.75 | RD / BU | 4540 | Battery Positive Voltage | I | - |
| F34Y | 0.5 | RD / VT | 4040 | Battery Positive Voltage | I | - |
| J1Y | 4 | RD / BU | 540 | Battery Positive Voltage | II | - |
| J2Y | 6 | RD / WH | 640 | Battery Positive Voltage | III | - |
| J3Y | 1.5 1.5 |
RD / WH RD / YE |
6440 6540 |
Battery Positive Voltage Battery Positive Voltage |
II | - - |
| J4Y | 1.5 1.5 |
RD / BN RD / BU |
6640 6740 |
Battery Positive Voltage Battery Positive Voltage |
II | - - |
| J5Y | 1.5 | RD / GN | 6140 | Battery Positive Voltage | II | - |
| J6Y | 1.5 | RD / WH | 2040 | Battery Positive Voltage | II | - |
| J8Y | 2.5 | RD / VT | 3340 | Battery Positive Voltage | II | - |
| R1_1 | 0.35 0.35 |
GY / GN GY / VT |
4083 755 |
Retained Accessory Power Relay 2 Coil Control Retained Accessory Power Relay Coil Control |
I I |
BTM -BTM |
| R1_2 | 0.5 | BK | 1550 | Ground | I | - |
| R2_1 | 0.5 | YE | 5704 | Endgate Latch Relay Coil Control | I | - |
| R2_2 | 0.5 | GN / BN | 5706 | Endgate Latch Relay Control | I | - |
| R2_3 | 0.5 | RD / GY | 3540 | Battery Positive Voltage | III | - |
| R2_5 | 0.5 | BU / WH | 6128 | Rear Closure Unlatch Actuator Unlatch Control | III | - |
| R4_1 | 0.5 | BK | 1550 | Ground | I | - |
| R4_2 | 0.35 | BN / VT | 5486 | Run Relay Coil Control | I | - |
| R4_3 | 4 | RD / GN | 6140 | Battery Positive Voltage | III | - |
| R4_5 | 3 | VT / BN | 341 | Run Ignition 3 Voltage | III | - |
| R5_1 | 0.35 | GY / VT | 3264 | Logistics Mode Relay Close Control | I | - |
| R5_2 | 0.35 | VT / BU | 3263 | Logistics Mode Relay Open Control | I | - |
| R5_3 | 1.5 | RD / GN | 6140 | Battery Positive Voltage | III | - |
| R5_5 | 2.5 | RD / VT | 6340 | Battery Positive Voltage | III | - |
| R5_6 | 0.5 | BK | 1550 | Ground | I | - |