Component Testing
WARNING: This page is about a different variant/trim than selected.
- Ignition/Vehicle - Off
- Disconnect the appropriate electrical connector:
- B193A Charge Air Cooler Air Temperature Sensor - Inlet
- B193B Charge Air Cooler Air Temperature Sensor - Outlet
- Test for 150 to 133, 900 ohms between the test points: Signal terminal 1 & Signal terminal 2
- If not between 150 and 133, 900 ohms
Replace the component: B193A Charge Air Cooler Air Temperature Sensor - Inlet or B193B Charge Air Cooler Air Temperature Sensor - Outlet
- Go to next step: If between 150 and 133, 900 ohms
- If not between 150 and 133, 900 ohms
- Verify the value is within the range listed in the table: Temperature Versus Resistance - Charge Air Cooler Temperature Sensor
- If not in the specified range
Replace the component: B193A Charge Air Cooler Air Temperature Sensor - Inlet or B193B Charge Air Cooler Air Temperature Sensor - Outlet
- Go to next step: If in the specified range
- If not in the specified range
- Test for infinite resistance between the test points: Each terminal of the component & The component's housing
- If less than infinite resistance
Replace the component: B193A Charge Air Cooler Air Temperature Sensor - Inlet or B193B Charge Air Cooler Air Temperature Sensor - Outlet
- Go to next step: If infinite resistance
- If less than infinite resistance
- All OK.